VERTICAL CABLE 047-WOS-0445 – 45 RMU 4-POST OPEN RACK ENCLOSURE
The 047-WOS-0445 is a 45 RMU, 4-post open rack enclosure built for network, server, and telecom equipment that’s deeper and heavier than a 2-post rack can handle. The rigid steel frame supports up to 1,322 lb (599.6 kg), with a 24 to 36 in depth range and a static-resistant powder-coated finish. With standard 19-inch spacing and pre-drilled #12-24 mounting holes, this open rack enclosure is a solid fit for data centers, server rooms, and colocation spaces.
KEY FEATURES
Here’s what makes the 047-WOS-0445 a dependable open rack enclosure:
- 45 RMU Open Frame: Plenty of rack space with easy access to equipment and cabling from the front and back.
- 4-Post Stability: A 4-post rack frame supports deeper and heavier equipment than a 2-post design.
- 1,322 lb (599.6 kg) Load Capacity: Heavy-duty steel construction supports dense equipment loads.
- 24 to 36 in Depth Range: Room for a wide range of network and server equipment depths.
- Standard 19-Inch Compatibility: Fits standard 19-inch rack equipment.
- Rigid Steel Frame with Unit Markings: Rack unit positions are marked to simplify equipment planning.
- Static-Resistant Powder-Coated Finish: Black finish resists static buildup, scratches, and corrosion.
- Pre-Drilled for #12-24 Screws: The classic mounting hole size for tapped-hole racks.
- Hardware Included: 40x #12-24 screws and washers, 3/8″ x 1″ UNF black bolts and nuts, 3/8″ flat washers, and assembly instructions.
- Ships in Two Boxes: One box for the poles and one for the base with hardware, for easy assembly.
- Manageable Weight: 61 lb (27.7 kg) for easier handling during setup.
APPLICATIONS
The 047-WOS-0445 open rack enclosure fits a wide range of installations:
- Data Centers: Rack servers, storage, switches, and patch panels with open-frame airflow and access.
- Server Rooms: Support deeper, heavier equipment that’s too much for a 2-post rack.
- Telecommunications Rooms: Organize network equipment and fiber enclosures in MDFs and IDFs.
- Colocation Facilities: Provide standardized, high-capacity mounting for multi-tenant deployments.
- Broadcast and AV: Rack audio/video gear, amplifiers, and distribution equipment with open-frame access.
WHY CHOOSE THE 047-WOS-0445 OPEN RACK ENCLOSURE?
Professionals choose the 047-WOS-0445 for its capacity, depth range, and open access. Here are 5 reasons to specify it for your next project:
- Built for Heavier Gear: 1,322 lb of capacity and a 4-post frame handle equipment a 2-post rack can’t.
- Room for Deeper Equipment: A 24 to 36 in depth range suits many servers and network devices.
- Open Access and Airflow: The open frame makes installation, cabling, and cooling easier.
- Easy to Set Up: Ships in two boxes with hardware included, and weighs just 61 lb.
- Fits Standard Gear: Standard 19-inch width and #12-24 holes accept equipment from most manufacturers.
GETTING IT INSTALLED?
Once the 047-WOS-0445 is on site, here’s how to set it up well:
- Plan your layout and weight first. Decide where each piece of gear goes before you load the rack, with heavier equipment lower in the frame, and stay under the 1,322 lb limit.
- Set the depth for your deepest gear. Use the 24 to 36 in range to match your equipment, and follow the included assembly instructions.
- Check your rail kits. The rack uses tapped #12-24 holes, so equipment is screwed in. If your servers use rail kits built for square holes, confirm they’ll work, or plan on shelves.
- Anchor and level it. Secure a tall, loaded rack to the floor where your site allows, and check local requirements for seismic bracing.
- Build in cable management and airflow. Add horizontal and vertical managers and a rack-mount PDU as you go, and keep the open frame clear for airflow.
For premium Open Racks & Accessories, visit Cabling Support Infrastructure and discover top-tier solutions today!