VERTICAL CABLE 047-WOS-0245 – 45 RMU 2-POST OPEN RACK ENCLOSURE
The 047-WOS-0245 is a 45 RMU, 2-post open rack enclosure for holding network gear, patch panels, and cable management in data centers, telecom rooms, and server rooms. The open frame provides easy front and rear access, and the rigid steel build supports up to 440 lb (199.6 kg) of equipment. With standard 19-inch spacing and a static-resistant powder-coated finish, this open rack enclosure is a dependable base for enterprise and colocation deployments.
KEY FEATURES
Here’s what makes the 047-WOS-0245 a dependable open rack enclosure:
- 45 RMU of Rack Space: Plenty of room for network equipment, patch panels, and cable management in one rack.
- 2-Post Open Frame: Easy access to equipment and cabling from the front, rear, and sides.
- 440 lb (199.6 kg) Load Capacity: Heavy-duty steel construction supports dense equipment loads.
- Standard 19-Inch Compatibility: Fits standard 19-inch rack equipment.
- Rigid Steel Frame with Unit Markings: Rack unit positions are marked to simplify equipment planning.
- Static-Resistant Powder-Coated Finish: Black finish resists static buildup, scratches, and corrosion.
- Pre-Drilled for #12-24 Screws: The classic mounting hole size for telco-style racks.
- Hardware Included: 28x #12-24 screws and washers (SKU 047-WSN-0600).
- Ships Unassembled: Flat shipping and straightforward assembly on site.
- Manageable Weight: Just 28 lb (12.7 kg) for easy handling during setup.
APPLICATIONS
The 047-WOS-0245 open rack enclosure fits a wide range of installations:
- Data Centers: Mount switches, patch panels, and cable management with open-frame airflow and access.
- Telecommunications Rooms: Organize network equipment and fiber enclosures in MDFs and IDFs.
- Server Rooms: Support network infrastructure as an easy-to-service 2-post rack.
- Colocation Facilities: Provide standardized mounting for multi-tenant network equipment.
- Broadcast and AV: Rack audio/video equipment, amplifiers, and distribution gear with accessible open-frame access.
WHY CHOOSE THE 047-WOS-0245 OPEN RACK ENCLOSURE?
Professionals choose the 047-WOS-0245 for its capacity, open access, and straightforward setup. Here are 5 reasons to specify it for your next project:
- Room to Grow: 45 RMU holds a lot of gear, so one rack can serve a full network room.
- Open Access: The 2-post frame makes installation, cabling, and maintenance easy from every side.
- Solid Steel Build: 440 lb of capacity supports dense deployments with confidence.
- Easy to Set Up: Ships unassembled with hardware included, and weighs only 28 lb.
- Fits Standard Gear: Standard 19-inch width and #12-24 holes accept equipment from most manufacturers.
GETTING IT INSTALLED?
Once the 047-WOS-0245 is on site, here’s how to set it up well:
- Match the gear to the rack. Two-post racks work best for patch panels, switches, and other lighter network equipment. Heavy or deep servers generally need extra support or a four-post rack.
- Plan your layout first. Decide where each piece goes before you start loading, with heavier items lower in the frame.
- Bolt it to the floor. Anchor a tall 2-post rack, and check local requirements for seismic areas that may require added bracing.
- Stay within the 440 lb limit. Add up the weight of everything you plan to mount, including cable management and power.
- Add cable management and power early. Horizontal and vertical managers and a rack-mount PDU are much easier to fit as you build than after the rack is full.
For more premium Open Racks & Accessories, visit Cabling Support Infrastructure and discover top-tier solutions today!