2-Post Open Rack Enclosures: Specs, Assembly, and Where They Fit


Vertical Cable’s 2-Post Open Rack Lineup

047-WOS-0220:
20 RMU 2-Post Open Rack

047-WOS-0245:
45 RMU 2-Post Open Rack

047-WOS-0245/2P:
45 RMU, 2-Section 2-Post Open Rack

SPEC
047-WOS-0220
047-WOS-0245
047-WOS-0245/2P
Rack Capacity
20 RMU
45 RMU
45 RMU
Usable Mounting Height
35 in. ( mm)
78.8 in. ( mm)
78.8 in. ( mm)
Height
40 in. (1,016 mm)
84 in. (2,133.6 mm)
84 in. (2,133.6 mm)
Width
20 in. (508 mm)
20.3 in. (515.6 mm)
20.3 in. (515.6 mm)
Depth
14 in. (355.6 mm)
14.8 in. (375.9 mm)
14.8 in. (375.9 mm)
Load Capacity
440 lbs. (199.6 kg)
804 lbs. (364.7 kg)
551.2 lbs. (250 kg)
Unit Weight
21 lbs. (9.5 kg)
28 lbs. (12.7 kg)
38 lbs. (17.2 kg)
Construction
Heavy-duty Steel Frame
Heavy-duty Steel Frame
Heavy-duty Steel Frame, 2 Sections
Finish
Scratch-resistant powder coat, Black
Scratch-resistant powder coat, Black
Scratch-resistant powder coat, Black
Mounting
Pre-drilled for #12-24 screws
Pre-drilled for #12-24 screws
Pre-drilled for #12-24 screws
Included Hardware
10 #12-24 screws and washers
28 #12-24 screws and washers
28 #12-24 screws and washers +
4 steel mounting plates
Best For
Small closets, AV/security, branch offices, labs
Full-height builds with the heaviest loads
Full-height builds with tight delivery routes

Why Choose a 2-Post Open Rack Over a 4-Post



Where Each 2-Post Open Rack Fits in Your Build-Out


Tools Required
  • 5 mm hex key wrench — included with the rack
  • Pliers or an adjustable wrench — required and NOT included
That second tool is easy to overlook. Step 2 has you hold each nut with pliers or a wrench while tightening the bolt with the Allen key, so a tech who shows up with only the included hex key can’t fully secure the frame connection.
Assembly Steps
1. Base angle bar assembly. Attach the front and rear base angle bars to the lower vertical frame sections using the supplied hex socket bolts, plain washers, and hex nuts. Leave the hardware loose for now. Make sure the RU markings face the front of the rack — much harder to correct once the frame is square.
2. Vertical frame connection. Join the upper and lower vertical frame sections with the supplied steel mounting plates. Each connection takes two brackets: one on the outside of the frame and one on the inside, both positioned over the pre-drilled holes at the joint. Install a washer with every bolt. Hold and tighten each bolt with the 5 mm Allen key while holding the nut with pliers or an adjustable wrench, and tighten securely while keeping the upper and lower sections aligned.
3. Top angle bar assembly. Attach the front and rear top angle bars to the upper vertical frame sections with the supplied hex socket bolts, washers, and nuts. Verify that all vertical frame sections are aligned and the rack is square before fully tightening all hardware.

45 RMU 2-Post Open Rack Enclosure | 047-WOS-0245/2P
The 45 RMU, 2-post open rack enclosure is designed to organize network equipment, patch panels, and cable management. Its heavy-duty steel construction supports up to 551.2 lbs (250 kg), while the open-frame design provides convenient front, rear, and side access. It accommodates standard 19-inch EIA-310 rack-mount equipment and features a static-resistant black powder-coated finish for long-lasting durability.

What’s the difference between 2-post and 4-post open racks?

How much weight can a 2-post open rack hold?

Should I choose a 20U or 45U 2-post rack?

Is a 2-post rack compatible with standard rack equipment?